Classification
Manufacturer
EClass
not containing the term:
Harvard Apparatus (BTX) 

Electroporation system Gemini Twin Wave X2, HT system

The Gemini Twin Wave devices are flexible systems that can generate both square wave and exponential decay waves. Ideally suited for all electroporation requirements. The waveform combination allows eukaryotic and prokaryotic cells to be electroporated easily and efficiently in cuvettes or plates with a single device. Prokaryotic cells typically respond well to exponential decay wave pulses, while eukaryotic cells are most efficiently transfected with square wave pulses.

  • Large, user-friendly touchscreen interface
  • Universal electroporation for transfection of cells in vitro, in vivo, in ovo, and adherent forms
  • Preset protocols include the most common eukaryotic and prokaryotic cell types
  • User-defined protocols: protocols can be added and modified without limits
  • Safety functions: Pre-pulse resistance check, arc protection, and over-current pulse abort
  • Data protocols store parameters of all delivered pulses for quality control and troubleshooting purposes
  • Storage of over 1000 protocols
With the supplied HT-200 plate handler, 96-well electroporation plates can be processed. The plate handler delivers a single pulse to the wells of the plate, using the parameters set in the generator.

Scope of supply: Generator Gemini X2, safety dome, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rack, HT-200 plate handler, electroporation plate 2 mm and 4 mm gap
Exponential decay pulse
Capacitance LV mode:25 ... 3275 µF
Capacitance HV mode:10, 25, 35, 50, 60, 75, 85 µF
Resistance LV mode:25 ... 1575 Ω
Resistance HV mode:50 ... 1575 Ω
Voltage LV mode:5 ... 500 V
Voltage HV mode:505 ... 3000 V
Multiple pulse:1 ... 2 (depending on amplitude limit of the device)
Pulse interval:5 ... 30 s
Square wave pulse
Capacitance LV mode:3775 µF
Capacitance HV mode:85 µF
Voltage LV mode:5 ... 500 V
Voltage HV mode:505 ... 3000 V
Multiple pulse single sample:1 ... 99 pulses per sample
Weight:7.3 kg
Permitted ambient conditions:4 ... 40 °C , 80 % RH
Power supply:100 ... 240 V, 50 ... 60 Hz
Electroporation system Gemini Twin Wave X2, HT system


Electroporation system Gemini Twin Wave X2, HT system
DescriptionDimensions (WxDxH)PKCat. No. 
Gemini X2 HT system286 x 216 x 324 mm14687935
Accessories:
Electroporation cuvettes Plus / Harvard Apparatus (BTX)
Alternate products:
Electroporation system Gemini Twin Wave X2, Complete system / Harvard Apparatus (BTX)
Electroporation system Gemini Twin Wave X2, Generator / Harvard Apparatus (BTX)