Classification
Manufacturer
EClass
not containing the term:
Eppendorf SE 

Benchtop centrifuges, 5810/5810 R without rotor (General Lab Product)

These centrifuges offer a flexible rotor program with a modular adapter system which can accommodate a high variety of tube lengths.

  • Ergonomic access height gives comfortable rotor loading
  • Low noise level
  • Motorized lid lock
  • Imbalance detector
  • Automatic rotor recognition logs rotor performance parameters and prevents these being exceeded
  • Optional user setting by speed, rcf or radius correction values
  • Values can be changed during centrifugation
  • Selectable programme memory for up to 34 individual user programmes
  • Short-spin function, speed can be preselected
  • 10 gentle acceleration and braking profiles for sensitive sample material


Additional features for refrigerated centrifuges:
  • Reliable cooling at maximum speed
  • Temperature setting from -9 °C to 40 °C
  • Standby cooling
  • Fast-cool function for rapid cooling of the centrifuge chamber
The Centrifuge 5810/5810 R is a workhorse for medium to high-throughput laboratories. It combines highversatility and capacity for both tubes and plates with an extraordinary compact footprint.

These centrifuges are General Lab Products for research purposes.

Please order rotors separately.
Power supply:230 V, 50/60 Hz
Benchtop centrifuges, 5810/5810 R without rotor (General Lab Product)


Benchtop centrifuges, 5810/5810 R without rotor (General Lab Product)
TypeMax. rcf
x·g
SpeedWith coolingTemperatureDimensions
(WxDxH)
Weight
kg
Rated capacity
W
Plug typePKCat. No. 
58102091314,000 1/minNo40 °C540 x 350 x 350 mm68900EU14660645
5810 R2091314,000 1/minYes-9 ... 40 °C700 x 350 x 350 mm991650EU14660655
58102091314,000 1/minNo40 °C540 x 350 x 350 mm68900UK14660646
5810 R2091314,000 1/minYes-9 ... 40 °C700 x 350 x 350 mm991650UK14660656
Accessories:
Fixed angle rotors for centrifuges 5804/5804 R, 5810/5810 R, incl. QuickLock® rotor lid / Eppendorf SE
Swing-out rotor A-4-44 for centrifuges 5804/5804 R, 5810/5810 R, incl. 4 rectangular buckets of 100 ml / Eppendorf SE
Swing-out rotor A-2-DWP for centrifuges 5804/5804 R, 5810/5810 R / Eppendorf SE
Swing-out rotor A-4-62 for centrifuges 5810/5810 R, incl. 4 x microtitre plate carriers / Eppendorf SE
Fixed angle rotor with steel sleeves F-35-48-17 for centrifuges 5804/5804 R, 5810/5810 R / Eppendorf SE
Swing-out rotors S-4-104 for centrifuges 5810/5810 R, without buckets / Eppendorf SE
Swing-out rotor A-4-81 for centrifuges 5810/5810 R, without buckets / Eppendorf SE
Swing-out rotor S-4-72 for centrifuges 5804/5804 R, 5810/5810 R, incl. 4 x 250 ml round buckets / Eppendorf SE
Swing-out rotor A-2-DWP-AT for centrifuges 5810/5810 R, incl. buckets, caps and plate carriers / Eppendorf SE
Swing-out rotor A-4-44 for centrifuges 5804/5804 R, 5810/5810 R, incl. 4 rectangular buckets for 2 x 50 ml / Eppendorf SE
Swing-out rotor A-4-62 for centrifuges 5810/5810 R, incl. 4 rectangular buckets of 250 ml / Eppendorf SE
Rotor stand for all rotors centrifuges 5804/5804 R/5810/5810 R / Eppendorf SE
Swing-out rotor A-4-81 for centrifuges 5810/5810 R, incl. 4 x 500 ml rectangular buckets / Eppendorf SE
Swing-out rotor A-4-81 for centrifuges 5810/5810 R, incl. 4 MTP/Flex-buckets / Eppendorf SE
Swing-out rotors S-4-104 for centrifuges 5810/5810 R, incl. 4 x 750 ml round buckets / Eppendorf SE
Swing-out rotor S-4-104 for centrifuges 5810/5810 R, incl. 4 plate buckets / Eppendorf SE
Drum rotor T-60-11 for centrifuges 5804/5804 R, 5810/5810 R / Eppendorf SE
Fixed angle rotors for centrifuges 5804/5804 R, 5810/5810 R, incl. rotor lid / Eppendorf SE