Classification
Manufacturer
EClass
not containing the term:
Macherey-Nagel 

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm

Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.
Octyl phases, 10.5 % C, particle size 5 µm.
Eluent in column:Acetonitrile/water
Particle type:Fully porous
Endcapped:Yes
Carbon content:10.5 %
pH stability:1 ... 9
Max. temp. resistance:60 °C
EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm


EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
MethodMaterial columnUSP listingSeparation systemParticle size
µm
Int. Ø
mm
Length
mm
Volume column
ml
PKCat. No. 
AnalyticalStainless steelL7Reverse phase52500.1514004521
AnalyticalStainless steelL7Reverse phase53500.3514004522
AnalyticalStainless steelL7Reverse phase54500.6214004523
AnalyticalStainless steelL7Reverse phase54.6500.8314004524
AnalyticalStainless steelL7Reverse phase521250.3714004525
AnalyticalStainless steelL7Reverse phase531250.8714004526
AnalyticalStainless steelL7Reverse phase541251.5614004527
AnalyticalStainless steelL7Reverse phase54.61252.0614004528
AnalyticalStainless steelL7Reverse phase54.61502.514004529
AnalyticalStainless steelL7Reverse phase522500.814004530
AnalyticalStainless steelL7Reverse phase532501.7514004531
AnalyticalStainless steelL7Reverse phase542503.1514004532
AnalyticalStainless steelL7Reverse phase54.62504.15016228531