Classification
Manufacturer
EClass
not containing the term:
Macherey-Nagel 

OPTIMA® 5 capillary columns for GC

5% phenyl - 95% dimethylpolysiloxane

USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films <3µm the max. temperature for isothermal operation is 340°C, the max. temperature for short isotherms in a temperature programme is 360°C for 0.53mm ID columns with films < 3µm the max. temperatures are 320 and 340°C, resp. for thick film columns with films ≥ 3µm the max. temperatures are 300 and 320°C, resp.

Further lengths available on request.
OPTIMA® 5 capillary columns for GC


OPTIMA® 5 capillary columns for GC
Material columnUSP listingPolarityFilm thickness
µm
Int. Ø
mm
Length
m
Temperature max isotherm
°C
Max. temperature programme
°C
PKCat. No. 
Quartz glassG27, G36Nonpolar0.10.11034036014003235
Quartz glassG27, G36Nonpolar0.10.252534036019003709
Quartz glassG27, G36Nonpolar0.250.252534036019003715
Quartz glassG27, G36Nonpolar0.350.252534036019003719
Quartz glassG27, G36Nonpolar0.50.252534036019003723
Quartz glassG27, G36Nonpolar10.252534036019003727
Quartz glassG27, G36Nonpolar0.10.253034036019003710
Quartz glassG27, G36Nonpolar0.250.253034036019003716
Quartz glassG27, G36Nonpolar0.350.253034036019003720
Quartz glassG27, G36Nonpolar0.50.253034036019003724
Quartz glassG27, G36Nonpolar10.253034036019003728
Quartz glassG27, G36Nonpolar0.10.255034036019003711
Quartz glassG27, G36Nonpolar0.250.255034036019003717
Quartz glassG27, G36Nonpolar0.350.255034036019003721
Quartz glassG27, G36Nonpolar0.50.255034036019003725
Quartz glassG27, G36Nonpolar10.255034036019003729
Quartz glassG27, G36Nonpolar0.10.256034036019003712
Quartz glassG27, G36Nonpolar0.250.256034036019003718
Quartz glassG27, G36Nonpolar0.350.256034036019003722
Quartz glassG27, G36Nonpolar0.50.256034036019003726
Quartz glassG27, G36Nonpolar10.256034036019003730
Quartz glassG27, G36Nonpolar0.10.322534036019003733
Quartz glassG27, G36Nonpolar0.250.322534036019003738
Quartz glassG27, G36Nonpolar0.350.322534036019003742
Quartz glassG27, G36Nonpolar0.50.322534036019003746
Quartz glassG27, G36Nonpolar10.322534036019003751
Quartz glassG27, G36Nonpolar30.322530032019003755
Quartz glassG27, G36Nonpolar50.322530032019003760
Quartz glassG27, G36Nonpolar0.10.323034036019003734
Quartz glassG27, G36Nonpolar0.250.323034036019003739
Quartz glassG27, G36Nonpolar0.350.323034036019003743
Quartz glassG27, G36Nonpolar0.50.323034036019003747
Quartz glassG27, G36Nonpolar10.323034036019003752
Quartz glassG27, G36Nonpolar30.323030032019003756
Quartz glassG27, G36Nonpolar50.323030032019003761
Quartz glassG27, G36Nonpolar0.10.325034036019003735
Quartz glassG27, G36Nonpolar0.250.325034036019003740
Quartz glassG27, G36Nonpolar0.350.325034036019003744
Quartz glassG27, G36Nonpolar0.50.325034036019003748
Quartz glassG27, G36Nonpolar10.325034036019003753
Quartz glassG27, G36Nonpolar30.325030032019003757
Quartz glassG27, G36Nonpolar0.10.326034036019003736
Quartz glassG27, G36Nonpolar0.250.326034036019003741
Quartz glassG27, G36Nonpolar0.350.326034036019003745
Quartz glassG27, G36Nonpolar0.50.326034036019003749
Quartz glassG27, G36Nonpolar10.326034036019003754
Quartz glassG27, G36Nonpolar30.326030032019003758
Quartz glassG27, G36Nonpolar0.50.532532034014003155
Quartz glassG27, G36Nonpolar10.532532034014003168
Quartz glassG27, G36Nonpolar20.532532034014003158
Quartz glassG27, G36Nonpolar50.532530032014003261
Quartz glassG27, G36Nonpolar0.50.533032034014003156
Quartz glassG27, G36Nonpolar10.533032034014003169
Quartz glassG27, G36Nonpolar20.533032034014003159
Quartz glassG27, G36Nonpolar50.533030032014003262
Quartz glassG27, G36Nonpolar20.535032034014003160
Quartz glassG27, G36Nonpolar50.535030032014003263
Quartz glassG27, G36Nonpolar20.536032034014003161
Custom-made columns to your specifications available on request.
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.
Additionally, we supply the corresponding test mixture with each column.